Maintenance
-
Make sure air supply is clean and dry - recommend using an air filter such as
part # TSD800-6
-
Avoid connecting air supply in excess of 100 psi (6.9 bar) for TS250 and 15 psi
(1.0 bar) for TS255
-
Avoid turning barrels upside down or laying barrel so that mate- rial may run
through airline to internal components - use inline filter for adapter #
881-000-000
-
Use amyl alcohol to clean surface of unit housing
-
Use soft cloth to clean LCD display
|