Extraction system unit for aerosol adhesives, lacquers, solvents, paints, solders, particles and dust. Spray adhesives, conformal coatings and paints, monomers, hazardous powders and particulates, resins, sealants, solders, light grinding particles, organic solvents and cleaners etc.
Capture, contain, filter and expel for a cleaner, healthier working environment within electronic design and rework, dental/medical labs, pharmaceutical labs, design and technology, science in education and more.
The workstation hood also accommodates prototypes, models, ceramic parts, PCBs etc, placed onto the hood base to be sprayed, soldered, cleaned, glued, moulded, sanded etc
.
Part ID: T500S-D Fan Motor Spec: 230V 50Hz 105W Air Volume at Free Air: 355 m3/hr Air Velocity at Filter Face: 0.50 m/sec Air Velocity at Hood Face: 0.32 m/sec Noise Level: 58 dB (A) Weight: 11 kg Commodity Code: 84213925 Origin: UK
Adhesive Dispensing Ltd provide a wide range of equipment options for dispensing almost all assembly fluids - from watery liquids, solvents, primers and activators through to thick pastes, sealants, silicones, gels and epoxies.
- Part ID: T500S-D
- Fan Motor Spec: 230V 50Hz 105W
- Air Volume at Free Air: 355 m3/hr
- Air Velocity at Filter Face: 0.50 m/sec
- Air Velocity at Hood Face: 0.32 m/sec
- Noise Level: 58 dB (A)
- Weight: 11 kg
Fan/filter casing (steel construction finished in dove grey) - clear PETG folding plastic fume shield - particulate (intake filter) - centrifugal blower, external rotor motor type, brushless, UL, VDE and CSA approved - sealed electrical wiring and switch, downstream of filter - flexi-duct 2 metres x 100mm dia. - carry handle.
All WS filtration systems and extraction systems carry a lifetime warranty, are quiet in operation and can be assembled in seconds. Place onto a desk, bench or trolley and then simply plug in and switch on. These units can be used in two positions.
The Flexi-duct can be fixed to a standard domestic vent or simply placed through a partially open window to facilitate portability and/or convenience. The folding PETG shield can be stored if not required thus reducing the unit footprint considerably. Handling and/or use of potentially harmful substances is carried out in front of the intake filter area.
The particulate (intake) filter is a three stage graduated fibre filter with a high 'dust' holding capacity for long life. Filtration to 5 micron particles. NB: Spray particulate sizes vary from 10 to 20 microns.
The dual process of filtration and then extraction to atmosphere via flexi-duct, vastly reduces and/or eliminates operator exposures to potentially hazardous substances.
This unit is designed for immediate operator protection whereby �large� particulates (> 5 microns) are filtered out and �fine� particulates (<5 microns) together with odours, gases, vapours and fumes within the intake filter zone are drawn through and exhausted to atmosphere via the flexi-duct.
Demonstrating adequate control of the risks to the health of employees students and the general public, from dusts, powders, mists, fumes and vapours is the fundamental requirement of the Control of Substances Hazardous to Health (CoSHH).
|